Temperature Data Logger EBI-125 A-EM-250-F1,6 with flexible probe Needle 250 and 500 mm |
|
Technical Data
|
| Type |
EBI 125A-EM-250-F1.6 |
Measuring range |
-40 to +125°C up to +140°C max. 1 h up to +135°C max. 3 h |
Accuracy |
±0.3°C |
Resolution
|
0.1°C |
| Sensor |
Pt1000
|
Needle
| Needle flexible, ø 1,5 mm 250 mm 1340-2146 500 mm 1340-2149 |
Measuring rate
|
from 1 s to 8 h |
Memory
|
18.000 readings |
Measuring modus
|
endless, Start/Stop |
Battery
|
3.6 V Lithium |
Battery life
|
3 t 5 years |
Housing material
|
stainless steel, PEEK |
Dimensions
|
Ø 48 x 28 mm high |
Protection class
|
IP 68 |
Weight
|
ca. 150 g |
Certificate
|
3 point factory calibration |
Interface
|
Interface EBI-KSY-AE 2000 |
|
| Attributes |
- Completely waterproof
- Temperature resistant up to +140°C
- Stainless steel housing, suitable for food products
- Small dimensions
- High accuracy
- Factory calibration certificate
- Different forms
- No wiring necessary
- Stainless steel probe, blunt
- External sensor
- Programming and evaluation with PC
- According to EN 285, 554, DIN 58946-6
- Probe ø 1.5mm
- Probe length 250mm
- FDA 21 Part 11 - conform
Available in needle lengths: 250 mm 1340-2146 500 mm 1340-2149 |
Accessories for Temperature Data Logger EBI-125 A-EM-250-F1,6 with flexible probe Needle 250 and 500 mm |
|
Interface-Set for EBI 85 A / 125 A Logger |
- EBI-AE-S Version C:
- Interface-Set for EBI-85 A / 125 A Logger
- incl. power supply, USB-adapter
- without Software
|
|
Type:
EBI-AE-S Vers. C
|
Product-No
1340-2074 |
|
|
|
EBI-DA Adapter-Set |
This adapter set provides elements for mechanically attaching the data logger to cans or plastic pouches.
|
|
Type:
EBI-DA-Set
|
Product-No
1340-1984 |
|
|
|
EBI-ID 114x160 Thermal Insulation Box |
- Thermal insulation box for temperature logger EBI 125 A-EM 500-F 1,6 in steam sterilizer
- Maximum dwell time at 180°C approx. 95 Minuten.
|
|
Type:
EBI-ID-114x160
|
Product-No
1340-1900 |
|
|
|
EBI-KSY-AE 2000 Interface-Set for EBI-85 A / EBI-1 / EBI-2 Logger (without Software) |
Interface for data logger EBI-85 A / EBI-125 A and EBI-2
|
|
Type:
EBI-KSY-AE 2000
|
Product-No
1340-2080 |
|
|
|
EBI-KSY-RS-232 Interface for EBI-2 Loggers (without Software) |
Interface for all EBI-2 data loggers, USB adapter on request
|
|
Type:
EBI-KSY-RS 232
|
Product-No
1340-2084 |
|
|
|
Clamp Connection EBI-KV3 for Data Logger EBI-125 A-EM |
This connection allows the user to accurately fix the logger probe to cans or glasses
|
|
Type:
EBI-KV3
|
Product-No
1340-2005 |
|
|
|
EBI-NI-140 Press-in nipple up to140°C (100 pcs.) |
Allows for precise fixing of logger probe in cans or jars
|
|
Type:
EBI-NI-140
|
Product-No
1340-1988 |
|
|
|
EBI-SSB-BD Thermal Insulation Box for Temperature/Pressure Logger |
- Silicone safety box for pressure/temperature data logger in steam sterlilizers
- Maximum dwell time at 150°C approx. 40 min.
|
|
Type:
EBI-SSB-BD
|
Product-No
1340-1898 |
|
|
|
EBI-SSB-EM Thermal Insulation Box for Temperture Logger |
Silicone insultion box for all EM-temperature loggers in steam sterilizers Maximum dwell time approx. 40 min. at 150°C
|
|
Type:
EBI-SSB-EM
|
Product-No
1340-1896 |
|
|
|
Additional License WINLOG 2000 Validated Version |
|
|
|
Type:
Winlog 2000 V folge
|
Product-No
1340-2342 |
|
|
|
Additional License WINLOG 2000 Validated Version |
|
|
|
Type:
Winlog 2000 V folge
|
Product-No
1340-2342 |
|
|
|
Software Winlog 2000-P |
- Graphical and numeric display of the temperature and pressure curve
- Scaling option
- User-defined functions
- Access codes
- Formula editor for calculating theoretical temperature
- A0 value 60, 600 and 3000
- F0 value
- Unit administration
- Protected against manipulation
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
- Pentium 350 MHz
- 64 MB RAM
- VGA graphic card
- Monitor
- Serial interface(RS 232)
- Mouse
- CD ROM
- Hard drive with minimum 100 MByte disk space
- Windows 9.x, ME, NT 4.0, 2000 or XP
- Printer
- xx pieces data logger
- Software EBI-WINLOG 2000 - Professional Version
|
|
Type:
WINLOG 2000-P
|
Product-No
1340-2310 |
|
|
|
Software Winlog 2000 Standard Version |
- Graphical and numeric display of the temperature and pressure curve
- Self-explanatory, can be operated immediately
- Online help
- Protected against manipulation
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
- 64 MB RAM
- VGA graphic card
- Monitor
- Serial interface (RS 232)
- Mouse
- CD ROM
- Hard drive with minimum 100 MByte disk space
- Windows 9.x, ME, NT 4.0, 2000 or XP
- Printer
- xx pieces data logger
- Software EBI-WINLOG 2000 - Standard Version
|
|
Type:
WINLOG 2000-S
|
Product-No
1340-2300 |
|
|
|
|
Validated Software Winlog 2000-V |
|
The complete system consisting of data loggers, interface and software WINLOG 2000-V is validated through TÜV Munich. The software WINLOG 2000-V is FDA 21 CFR Part 11 conform. It includes electronic signature, access codes, audit trail and is secure against manipulation. IQ, OQ, PQ and SOP can be purchased for the system. Additionally, the validated version WINLOG 2000 software offers all functions of the professional and BUS versions. Professional Version WINLOG 2000-P:
- Graphical and numeric display of the temperature and pressure curve
- Scaling option
- User-defined functions
- Access codes
- Formula editor for calculating theoretical temperature
- A0 value 60, 600 and 3000
- F0 value
- Unit administration
- Protected against manipulation
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
BUS-Version WINLOG 2000-B: - Automatic recording of the temperature values in store rooms, blood and plasma coolers, etc.
- Automatic programming and readout via PC and wireless transmission
- Automatic alarm per PC or wireless transmission
- Up to 63 data loggers can be monitored
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
- Pentium 350 MHz
- 64 MB RAM
- VGA graphic card
- Monitor
- Serial interface (RS 232)
- Mouse
- CD ROM
- Hard drive with minimum 100 MByte disk space
- Windows 9.x, ME, NT 4.0, 2000 or XP
- Printer
- xx pieces data loggers
- Software EBI-WINLOG 2000 - Validated Version
|
|
Type:
WINLOG 2000-V
|
Product-No
1340-2340 |
|
|
|
German Handbook for Software WINLOG 2000 |
|
|
|
Type:
WINLOG Handbuch
|
Product-No
1340-2350 |
|
|
|