Technical Data
|
Measuring range
|
-40 to +85°C |
Accuracy
|
±0.3°C |
Resolution
|
0.1°C |
Memory
|
18.000 values
|
Measuring mode
|
endless, Start/Stop or Start with set measuring rate
|
Measuring rate
|
freely programmable from 1 s to 8h (1s is equivalent to measuring duration of 5 h) |
Battery life
|
typical 8 years
|
Logger housing
|
Stainless steel , PEEK, waterproof IP 68 |
Pressure resistance
|
up to 20 bar |
Temperature sensor
|
Pt 1000 1/3 DIN Klasse B |
Certificate
|
3 point factory calibration
|
|
| Attributes |
- Pressure resistant up to 20 bar
- Waterproof IP 68
- 18.000 values
- Resistant against manipulation
- Software
- Factory calibration certificate
- FDA 21 Part 11 - conform
Data Logger EBI 85-A is also available in Ex-Version:
Description Type Article No. Temperature Data Logger -20°C ... +60°C Ex-approved EBI 85-A-Ex 1340-1904 |
Accessories for Temperature Data Logger EBI-85 A waterproof IP 68 |
|
Interface-Set for EBI 85 A / 125 A Logger |
- EBI-AE-S Version C:
- Interface-Set for EBI-85 A / 125 A Logger
- incl. power supply, USB-adapter
- without Software
|
|
Type:
EBI-AE-S Vers. C
|
Product-No
1340-2074 |
|
|
|
EBI-ID 114x160 Thermal Insulation Box |
- Thermal insulation box for temperature logger EBI 125 A-EM 500-F 1,6 in steam sterilizer
- Maximum dwell time at 180°C approx. 95 Minuten.
|
|
Type:
EBI-ID-114x160
|
Product-No
1340-1900 |
|
|
|
EBI-KSY-AE 2000 Interface-Set for EBI-85 A / EBI-1 / EBI-2 Logger (without Software) |
Interface for data logger EBI-85 A / EBI-125 A and EBI-2
|
|
Type:
EBI-KSY-AE 2000
|
Product-No
1340-2080 |
|
|
|
USB-Adapter |
|
|
|
Type:
EBI-KSY-USB
|
Product-No
1900-0100 |
|
|
|
EBI-SSB-BD Thermal Insulation Box for Temperature/Pressure Logger |
- Silicone safety box for pressure/temperature data logger in steam sterlilizers
- Maximum dwell time at 150°C approx. 40 min.
|
|
Type:
EBI-SSB-BD
|
Product-No
1340-1898 |
|
|
|
EBI-SSB-EM Thermal Insulation Box for Temperture Logger |
Silicone insultion box for all EM-temperature loggers in steam sterilizers Maximum dwell time approx. 40 min. at 150°C
|
|
Type:
EBI-SSB-EM
|
Product-No
1340-1896 |
|
|
|
Software Winlog 2000-P |
- Graphical and numeric display of the temperature and pressure curve
- Scaling option
- User-defined functions
- Access codes
- Formula editor for calculating theoretical temperature
- A0 value 60, 600 and 3000
- F0 value
- Unit administration
- Protected against manipulation
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
- Pentium 350 MHz
- 64 MB RAM
- VGA graphic card
- Monitor
- Serial interface(RS 232)
- Mouse
- CD ROM
- Hard drive with minimum 100 MByte disk space
- Windows 9.x, ME, NT 4.0, 2000 or XP
- Printer
- xx pieces data logger
- Software EBI-WINLOG 2000 - Professional Version
|
|
Type:
WINLOG 2000-P
|
Product-No
1340-2310 |
|
|
|
Software Winlog 2000 Standard Version |
- Graphical and numeric display of the temperature and pressure curve
- Self-explanatory, can be operated immediately
- Online help
- Protected against manipulation
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
- 64 MB RAM
- VGA graphic card
- Monitor
- Serial interface (RS 232)
- Mouse
- CD ROM
- Hard drive with minimum 100 MByte disk space
- Windows 9.x, ME, NT 4.0, 2000 or XP
- Printer
- xx pieces data logger
- Software EBI-WINLOG 2000 - Standard Version
|
|
Type:
WINLOG 2000-S
|
Product-No
1340-2300 |
|
|
|
|
Validated Software Winlog 2000-V |
|
The complete system consisting of data loggers, interface and software WINLOG 2000-V is validated through TÜV Munich. The software WINLOG 2000-V is FDA 21 CFR Part 11 conform. It includes electronic signature, access codes, audit trail and is secure against manipulation. IQ, OQ, PQ and SOP can be purchased for the system. Additionally, the validated version WINLOG 2000 software offers all functions of the professional and BUS versions. Professional Version WINLOG 2000-P:
- Graphical and numeric display of the temperature and pressure curve
- Scaling option
- User-defined functions
- Access codes
- Formula editor for calculating theoretical temperature
- A0 value 60, 600 and 3000
- F0 value
- Unit administration
- Protected against manipulation
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
BUS-Version WINLOG 2000-B: - Automatic recording of the temperature values in store rooms, blood and plasma coolers, etc.
- Automatic programming and readout via PC and wireless transmission
- Automatic alarm per PC or wireless transmission
- Up to 63 data loggers can be monitored
- Available in 19 languages: English, French, German, Italian,
Spanish, Dutch, Swedish, Danish, Norwegian, Finnish, Portuguese, Greek,
Czech, Polish, Japanese, Slovenian, Turkish, Hungarian, Chinese
- Pentium 350 MHz
- 64 MB RAM
- VGA graphic card
- Monitor
- Serial interface (RS 232)
- Mouse
- CD ROM
- Hard drive with minimum 100 MByte disk space
- Windows 9.x, ME, NT 4.0, 2000 or XP
- Printer
- xx pieces data loggers
- Software EBI-WINLOG 2000 - Validated Version
|
|
Type:
WINLOG 2000-V
|
Product-No
1340-2340 |
|
|
|
German Handbook for Software WINLOG 2000 |
|
|
|
Type:
WINLOG Handbuch
|
Product-No
1340-2350 |
|
|
|